News / efflock to prevent rising damp
-
Mar 14, 2013
Capillary action
Read more →Capillary action (also known as wicking) is a common problem in buildings. Like the very action we depend on, of blood flowing through our bodies capillaries to our extremities, water can also flow and be drawn along or through many building materials. Roof leaks are one example where capillary action is often responsible. Picture: Capillary action on a clay brick. Ordinary tile screed of the same sample size would reach total saturation in around 10 minutes . Concrete and masonry, even of high quality contains capillaries. Common problems we see that arise from water flowing through concrete include: Concrete...
-
Mar 04, 2013
Efflock is a sustainable product choice
Read more →Efflock is 100% VOC free. Being water based and solvent free, also means Efflock is not flammable and has no offensive or dangerous odour. Efflock's maximum concentrate formula also means minimal plastic packaging waste and minimal fossil fuel consumption through transport. Sustainability Through Longevity: Production of masonry products like tiles, bricks and cement by nature, demand a carbon hungry manufacturing process. Each of these materials however, are some of the most versatile and useful building materials we have, and can be very long lasting when installed with diligence. Increasing the 'service life' of each of these building materials...
-
Mar 01, 2013
Efflock to prevent rising damp and salt attack in buildings
Read more →Photograph showing rising damp and subsequent salt attack below DPC level. Rising damp is destructive for buildings. It is well understood that damp very quickly will create rot in structural timbers such as bearers and joists, and therefore a DPC (damp proof course) is provided to prevent rising damp. A modern DPC is typically a black embossed polythene roll that is laid out directly beneath ant-capping, or just below finished ground floor level. Polyethelene underlay (black or orange plastic) serves the same purpose for slab on ground construction. What is not usually considered, is that rising damp can also have destructive consequences...
-
Oct 27, 2012
Efflock test with salt water samples
Read more →We've put Efflock to the test with exactly what you should not do to concrete! Pictured are two samples of 4 sand: 1 cement each made with 140mls of straight sea water from Coogee Bay off the coast of Sydney. They have been cured and placed in a dish of water to test their water repellency. In the foreground is the Efflock sample. Even with salt water in the concrete mix there is clearly no wicking effect! Without water able to dissolve salts and free lime, efflorescence cannot occur.